Rtrv-Attr - Keywords And Values For All <Aids - Symmetricom TimeProvider 1100 Reference Manual

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Parameter
<aid>
cont'd
Table 2-10. RTRV-ATTR – Keywords and Values for all <aids>
<keyword>
Alarm ID
The identifier of the alarm for which the level is to be retrieved.
Notes:
(null) or ALL
Retrieves alarm attributes that are associated with all alarms
that are related to the specified <aid>.
Command Output
The following shows the output format of the command, and
various fields in the command output:
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M
ctag COMPLD<cr><lf>
"<aid>:alarm id,alarm level"<cr><lf>
"<aid>:alarm id,alarm level"<cr><lf>
.
"<aid>:alarm id,alarm level"<cr><lf>
;
097-58001-01 Revision E – September 2006
Value
See
OUTg
Retrieves the alarm level(s) set for all alarms related to the
specified Output module.
g = "A" for the group marked "A" on the main shelf
g = "B" for the group marked "B" on the main shelf
g = "C" for the group marked "C" on the main shelf
g = "D" for the group marked "D" on the main shelf
E422g
Retrieves the alarm level(s) set for all alarms related to the
specified EIA-422 output module.
g = "A" for the group marked "A" on the main shelf
g = "B" for the group marked "B" on the main shelf
g = "C" for the group marked "C" on the main shelf
g = "D" for the group marked "D" on the main shelf
Description
See
Table B-1
for the possible alarm identifiers.
This keyword is not valid if the <aid> is ALL or null.
Chapter 2 TL1 Command Syntax and Description
Retrieve Attribute (RTRV-ATTR)
Description
Table 2-10
for <keyword> descriptions.
Table 2-11
TimeProvider TL1 Reference Guide
Default
N/A
N/A
explains the
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents