Appendix C Events
Table C-1. Event Identifiers (Continued)
Event ID
or
Event Description
CONDTYPE
CLKFSTLK
The local oscillator on the
specified IOC is in
Fast-Lock mode
CLKLOCK
The local oscillator on the
specified IOC is in Lock
mode
SCAVAIL
The specified IOC
module was tracking a
reference for at least 32
Hours, allowing the
SmartClock algorithm to
be engaged.
CKTIDCHG A user has modified the
Circuit ID for the input.
CRCENA
Allows the user to
provision the E1 (CAS/
CCS) inputs to enable or
disable the use of CRC4
checking. If the E1 input
is provisioned to read
SSMs, CRC4 is
automatically enabled.
FRMTYPE
Allows the user to
provision the type of input
framing or the input
frequency.
Allows the user to
provision the output
framing type.
162 TimeProvider TL1 Reference Guide
AID
Default Value
TYPE
IOC Clock Event Codes
EQPT NA
EQPT NA
EQPT OFF
Input Event Codes
T1
GPS
T1
DISABLE
T1
PRC INPUT =
2M
INPUT 1 = 2M
INPUT 2 = 2M
Value Description
NA
NA
ON – SmartClock is available.
OFF – SmartClock is not
available
The ID can be up to 40 characters
in length.
ENABLE | DISABLE
1.544M – 1.544 MHz
2M – 2.048 MHz
5M – 5 MHz
6.312M – 6.312 MHz
10M – 10 MHz
CAS – CAS Input
CCS – CCS Input
D4 – Super Frame Input
ESF – Extended Super Frame
Input
CC – Composite Clock Input
JCC – G.703 64K/8K
JCC4 – G.703 64K/8K/0.4K