Table B-1. Alarms (Continued)
Alarm ID
Alarm Condition
or
Description
CONDTYPE
INPLOS
The 1PPS from GPS is
LOS. The LOS must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPLOS is set, the
alarm clears when the
input signal is LOS free
for the Clear Delay Time
(CLRDELAY).
INPPHASE
The specified input port
has a excessive phase
measurement that
disqualifies it from being
used.
EXDSC
Input has had excessive
discontinuities. This is
indicated when there
are more than 3 signals
faults of the same type
within a 5-minute
window. The alarm
clears when the 5-
minute window contains
less than 3 alarms of the
same type.
FFOFF
Input has exceeded the
Fractional Frequency
Offset threshold.
MTIE
Input has exceeded at
least one of the MTIE
alarm thresholds.
TPIUSIG
TimeProvider
Composite Timing
Signal interface is not
functioning
097-58001-01 Revision E – September 2006
Error
AID
Service
Delay
Type
Affecting
Default
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
Appendix B Alarms
Alarm Default
Error
Level
Delay
Editable
SSU PRS SUB
NO
MN
MN
NO
MN
MN
NO
MN
MN
NO
MN
MN
NO
MN
MN
NO
MN
MN
TimeProvider TL1 Reference Guide 147
MN
MN
MN
MN
MN
MN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents