Syntax
ED-EQPT:[<tid>]:NTP:[<ctag>]::KEYGEN,<func>,<keyid>[,<key>];
<keyword>
<value>
FUNC
ADD | DELETE
| MODIFY
KEY
32-character
ASCII value
KEYID
1 to 65534
Example
To add an NTP authentication key:
Input
ED-EQPT::NTP:TP1000::KEYGEN,ADD,ABC...XYZABCDEF,1024;
Normal Response
TP-SSU 05-02-10 13:35:56
M
TP1000 COMPLD
;
Autonomous Message
TP-SSU 05-02-10 13:35:56
A 2537 REPT EVT
"NTP,EQPT:SERVER,TC,05-02-10,13-35-56,,,,:\"NTP AUTHENTICATION HAS
CHANGED\""
;
097-58001-01 Revision E – September 2006
Description
Key to be added, deleted, or modified
Authentication key
The Authentication identification value
Chapter 2 TL1 Command Syntax and Description
ED-EQPT for NTP Parameters
NA
Null
1
TimeProvider TL1 Reference Guide
Default
53