Table C-1. Event Identifiers (Continued)
Event ID
or
Event Description
CONDTYPE
INPREF
The specified input was
selected as system
reference. The possible
references includes PRS,
INP1, or INP2. GPS is
reference in PRR mode
only
IOCMODE
When an IOC becomes
the Active it generates an
event.
IOCSTATE
The specified IOC
module was inserted into
the system. The module
is automatically
Placed-In-Service.
The User has specified
the IOC module be taken
"Out of Service". OOSRV
prevents the module from
generating alarms or
being provisioned or
queried for provisioned
settings, etc.
RESET
When the IOC is
commanded to reset, it
generates an event
indicating that it is being
restarted.
Prior to restarting all
alarms associated with
the specified IOC is
cleared. Prior to
restarting, if the IOC is
the Active IOC it is
successfully placed in
Standby mode.
SYSMODE
Configures the systems
mode of operation.
097-58001-01 Revision E – September 2006
AID
Default Value
TYPE
EQPT PRS
EQPT ACTIVE
EQPT INSRV
EQPT INSRV
EQPT NA
EQPT SSU
Appendix C Events
Value Description
GPS | PRS | INP1 | INP2
ACTIVE | STANDBY
INSRV – In Service
OOSRV – Out of Service
NA
SSU – Sync Supply Unit mode
of operation
SUB – Subtending TSG mode
of operation
PRR – Primary Reference
Receiver mode of operation
TimeProvider TL1 Reference Guide 161