Appendix C Events
Table C-1. Event Identifiers (Continued)
Event ID
or
Event Description
CONDTYPE
KEYGEN
Indicated that the
Authentication Key table
is being generated
SERVER
Indicates that a user has
changed the NTP Peer
Server parameters.
BRDGTIM
Bridging Time, in PRR
mode the amount of time
the system stays in
Bridging Mode
CLRDELAY The time, in seconds,
before a faulted signal
indicates it is valid to be
used as a system
reference.
ELEVTIME
The alarm elevation time
(1440 minutes) was
Enabled or Disabled.
FACTORY
When the SYS is
commanded to reset to
Factory defaults, it
generates an event
indicating the factory
settings are being
restored. This resets all
modules installed in the
system at the time the
command is issued.
FLTDELAY
The time, in seconds,
before a faulted signal
indicates it is not valid to
be used as a system
reference.
166 TimeProvider TL1 Reference Guide
AID
Default Value
TYPE
EQPT NA
EQPT NA
SYS Event Codes
EQPT 900 seconds
EQPT 5 seconds
EQPT DISABLE
EQPT NA
EQPT 5 seconds
Value Description
NA
NA
300 to 500000 seconds | DISABLE
0 to 1000 seconds
ENABLE | DISABLE
NA
1 to 15 seconds
097-58001-01 Revision E – September 2006