Table 2-6. ED-SYNC – Keywords and Values (Continued)
<keyword>
<value>
HOLDFLT
CUTTHRU
RETIME
FRMTYPE
1.544M
2M
FREEFLT
ON
SQUELCH
HOLDFLT
ON
SQUELCH
Note:
1
Used only in Japanese version.
Example
To provision the interface type of the inputs as T1 inputs:
Input
ED-SYNC::INP1:TP1000::FRMTYPE=D4;
Normal Response
TP-SSU 05-02-10 13:35:56
M
TP1000 COMPLD
;
Autonomous Message
TP-SSU 05-02-10 13:35:56
A 2556 REPT EVT
"INP1,T1:FRMTYPE,TC,05-02-10,13-35-56,,,,:\"INPUT FRAMING TYPE HAS
CHANGED,D4\""
;
097-58001-01 Revision E – September 2006
Description
Cut-thru mode is engaged when the Local Oscillator
enters Holdover mode.
Cut-thru mode is not engaged when the Local
Oscillator enters Holdover mode.
<aid> = E422g
The framing type generated by the specified EIA-422
output group is provisioned as 1.544 MHz.
The framing type generated by the specified EIA-422
output group is provisioned as 2 MHz.
Outputs are generated when the Local Oscillator
enters Free-run mode.
Outputs are squelched (turned off) when the Local
Oscillator enters Free-run mode.
Outputs are generated when the Local Oscillator
enters Holdover mode.
Outputs are squelched (turned off) when the Local
Oscillator enters Holdover mode.
Chapter 2 TL1 Command Syntax and Description