Appendix B Alarms
Table B-1. Alarms (Continued)
Alarm ID
Alarm Condition
or
Description
CONDTYPE
INPFRQ
The specified input port's
calculated received
frequency is exceeding
the pull-in range of the
local oscillator. The
received signal's
calculated frequency
alarmed condition
disqualifies the input as
a possible reference.
After INPFRQ is set, the
alarm clears when the
input frequency is within
the defined pull-in range
limits.
INPTRR
The specified CC input
port has a Tip/Ring
reversal on it's
connection to the system.
EXDSC
Input has had excessive
discontinuities. This is
indicated when there
are more than 3 signal
faults of the same type
within a 5-minute
window. The alarm
clears when the 5-
minute window contains
less than 3 alarms of the
same type.
MTIE
Input has exceeded at
least one of the MTIE
alarm thresholds.
E422FAULT
The EIA-422 Output
module is not functioning.
<aid> = RTMA[-p] | RTMB[-p] | RTMC[-p]. | RTMD[-p]
S1LOS
LOS on Side 1
S2LOS
LOS on Side 2
EXSLIP
Excessive Slip Rate
RTMFAULT
The Retimer module is
not functioning properly
152 TimeProvider TL1 Reference Guide
AID
Service
Type
Affecting
T1
NSA
T1
NSA
T1
NSA
T1
NSA
<aid> = E422A | E422B | E422C | E422D
T1
NSA
T1
NSA
T1
NSA
T1
NSA
T1
NSA
Error
Error
Delay
Delay
Default
Editable
SSU PRS SUB
IMMED
NO
MN
IMMED
NO
MN
IMMED
NO
MN
IMMED
NO
MN
IMMED
NO
NA
IMMED
NO
MN
IMMED
NO
NA
IMMED
NO
NA
IMMED
NO'
NA
097-58001-01 Revision E – September 2006
Alarm Default
Level
MN
NR
MN
MN
MN
MN
MN
MN
NA
NA
MN
MN
NA
NA
NA
NA
NA
NA