Omron R88M-K User Manual page 429

Ac servomotors/servo drives g5-series with built-in ethercat communications
Hide thumbs Also See for R88M-K:
Table of Contents

Advertisement

Position Command Filter Time Constant
3222 hex
Setting range
0 to 10000
Size
2 bytes (INT16)
• The Position Command Filter Time Constant is the first-order lag filter that is inserted after the
electronic gear ratio for the command input.
• This constant is used to reduce the stepping movement of the motor and achieve a smooth operation
when the electronic gear ratio is set in 10 times or greater.
• It sets the first-order lag filter time constant, as shown below, for the square-wave command of target
speed Vc.
Input position command
Speed
Target speed Vc
*1
Vc × 0.632
Vc × 0.368
*1
*1 The error in the position command filter time constant is 0.4 max. (absolute error) for less than 100 ms and 0.2% max.
(relative error) for 20 ms or greater for the set value times 0.1 ms.
*2 The Position Command Filter Time Constant (3222 hex) is switched when the position command value per 0.250 ms
changes from 0 to a value other than 0 while the positioning completed output is ON.
*3 There is a delay from when the Position Command Filter Time Constant (3222 hex) is changed until the new value is
applied in internal calculations. If the filter switch wait time expires during this delay, the change may be placed on hold.
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Unit
0.1 ms
Access
t
f
t
= (3222 hex
*3
× 0.1 ms)
f
9 Details on Servo Parameter Objects
Default setting
0
RW
PDO map
Position command after
the smoothing filter process
t
f
Filter switching
dwell time
*2
csp pp hm
Data attribute
B
Not possible.
Time
9-25
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kn-ect

Table of Contents