*2 Applicable load inertia.
• The operable load inertia ratio (load inertia/rotor inertia) depends on the mechanical configuration and its
rigidity. For a machine with high rigidity, operation is possible even with high load inertia. Select an
appropriate motor and confirm that operation is possible.
• The dynamic brake is intended for emergency stop and therefore has a short-time rating.
If the dynamic brake is activated, allow it to be in a stop state for 3 minutes or more to prevent a circuit failure
and burning of the Dynamic Brake Resistor.
*3 The allowable radial and thrust loads are the values determined for a limit of 20,000 hours at normal operating
temperatures.
The allowable radial loads are applied as shown in the following diagram.
*4 This is a non-excitation brake. (It is released when excitation voltage is applied.)
*5 The operation time is the value (reference value) measured with a surge suppressor (CR50500 by Okaya
Electric Industries Co., Ltd.).
*6 Direct current switching with a varistor (TNR9G820K by Nippon Chemi-Con Corporation).
*7 Direct current switching with a varistor (Z15D151 by Ishizuka Electronics Co.).
Torque-Rotation Speed Characteristics for 1,000-r/min Servomotors
• 1,000-r/min Servomotors (200/400 VAC)
The following graphs show the characteristics with a 3-m standard cable and a 200-VAC input.
• R88M-K90010H/T/F/C
(900 W)
Power supply voltage
(N • m)
dropped by 10%
19.3
19.3(1800)
(1600)
20
14.0
Momentary operation range
8.59
8.59
10
8.0
4.3
Continuous operation range
0
1000
2000 (r/min)
• R88M-K4K510T/C (900 W)
(N • m)
107.0
(1500)
107.0(1700)
Power supply
100
voltage dropped
by 10%
Momentary operation range
70.0
50
43.0
43.0
50.0
22.0
Continuous operation range
2000 (r/min)
0
1000
Note 1 The continuous operation range is the range in which continuous operation is possible. Continuous operation at the
maximum speed is also possible. However, doing so will reduce the output torque.
2 If the motor power cable exceeds 20 m, the voltage drop will increase and the momentary operation range will
become narrower.
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Radial load
Thrust load
Shaft center (LR/2)
• R88M-K2K010H/T/F/C
(2 kW)
(N • m)
47.7
(1400)
47.7(1600)
50
Power supply
voltage dropped
by 10%
Momentary operation range
28.0
25
19.1
19.1
18.0
9.6
Continuous operation range
0
1000
2000 (r/min)
• R88M-K6K010T/C (900 W)
(N • m)
143.0
(1500)
143.0(1700)
150
Momentary operation range
75
57.3
57.3
Continuous operation range
0
1000
2000 (r/min)
• R88M-K3K010H/T/F/C
(3 kW)
(N • m)
71.7
(1400)
70
Momentary operation range
35
28.7
28.7
Continuous operation range
0
1000
Power supply
voltage dropped
by 10%
100.0
57.3
28.0
3 Specifications
71.7(1600)
Power supply
voltage dropped
by 10%
40.0
20.0
14.0
2000 (r/min)
3-57
3