logging event power-inline-status

To enable the logging of Power over Ethernet (PoE) events, use the logging event power-inline-status
command in interface configuration mode. To disable the logging of PoE status events, use the no form of
this command.
logging event power-inline-status
no logging event power-inline-status
Syntax Description
This command has no arguments or keywords.
Command Default
Logging of PoE events is enabled.
Command Modes
Interface configuration
Command History
Release
Cisco IOS XE 3.3SE
Usage Guidelines
The no form of this command does not disable PoE error events.
Examples
This example shows how to enable logging of PoE events on a port:
Device(config-if)# interface gigabitethernet1/0/1
Device(config-if)# logging event power-inline-status
Device(config-if)#