logging event power-inline-status

logging event power-inline-status
Use the logging event power-inline-status interface configuration command to enable or disable the
logging of Power over Ethernet (PoE) events. Use the no form of this command to disable the logging
of PoE status events; however, the no form of this command does not disable PoE error events.
Syntax Description
power-inline-status
Defaults
The default is enabled.
Command Modes
Interface configuration
Command History
Release
12.1(19)EA1
Usage Guidelines
The power-inline-status keyword is not available on Gigabit Ethernet interfaces on PoE switches, nor
is it available on non-PoE switches.
Examples
This example shows how to enable logging of PoE events on a port:
Switch(config-if)# interface fastethernet1/0/1
Switch(config-if)# logging event power-inline-status
Switch(config-if)#
Related Commands
Command
power inline
show controllers
power inline
Catalyst 3750 Switch Command Reference
2-128
logging event power-inline-status
no logging event power-inline-status
Enables the logging of PoE messages.
Modification
This command was introduced.
Description
Enables or disables power for the specified PoE port or for all PoE ports.