Command Reference, Cisco Ios Xe Everest 16.5.1A (Catalyst 3650 Switches - Cisco Catalyst 3650 series Command Reference Manual

Cisco ios xe everest 16.5.1a
Hide thumbs Also See for Catalyst 3650 series:
Table of Contents

Advertisement

show power inline
Gi1/0/1
Gi1/0/2
Gi1/0/3
Gi1/0/4
Gi1/0/5
Gi1/0/6
Gi1/0/7
Gi1/0/8
Gi1/0/9
Gi1/0/10
Gi1/0/11
Gi1/0/12
Gi1/0/13
<output truncated>
In the previous example:
• The Gi1/0/1 port is shut down, and policing is not configured.
• The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog message.
• The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
• Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is disabled.
• Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing is
enabled with a policing action to generate a syslog message.
• Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing is
enabled with a policing action to shut down the port.
• The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
• The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message, but
the switch does not apply power to the powered device.
• The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
• The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
• The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.
• The Gi1/0/12 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
• The Gi1/0/13 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port.
This is an example of output from the show power inline police interface-id command on a standalone switch.
The table that follows describes the output fields.
Device> show power inline police gigabitethernet1/0/1
Interface Admin
--------- ------ ---------- ---------- ---------- ------ -----
Gi1/0/1

Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)

118
auto
off
none
auto
off
log
auto
off
errdisable n/a
off
off
none
off
off
log
off
off
errdisable n/a
auto
off
none
auto
off
log
auto
on
none
auto
on
log
auto
on
log
auto
on
errdisable ok
auto
errdisable
errdisable n/a
Oper
Admin
State
State
Police
auto
off
none
n/a
n/a
0.0
n/a
5.4
0.0
5.4
0.0
n/a
n/a
0.0
n/a
5.4
0.0
5.4
0.0
n/a
n/a
0.0
n/a
5.4
0.0
n/a
n/a
5.1
ok
5.4
4.2
log
5.4
5.9
5.4
4.2
5.4
0.0
Oper
Cutoff Oper
Police
Power
Power
n/a
n/a
0.0