A Appendix; For Customers Replacing The Conventional Model With This Inverter; Replacement Of The Fr-F700(P) Series; A.1 For Customers Replacing The Conventional Model With This Inverter - Mitsubishi Electric FR-F820-00077 Instruction Manual

Fr-f800 series
Hide thumbs Also See for FR-F820-00077:
Table of Contents

Advertisement

Appendix
A
Appendix
A.1
For customers replacing the conventional model with this
inverter
A.1.1

Replacement of the FR-F700(P) series

Differences and compatibility with the FR-F700(P) series
Item
Control method
Added functions
Maximum output frequency
V/F control
PID control
Automatic restart after
instantaneous power failure
PTC thermistor input
USB connector
Main circuit terminal screw size
Control circuit terminal block
Terminal response level
PU
Plug-in option
Plug-in option connector
Communication option
Installation size
Tab. A-1:
FR-F800

For customers replacing the conventional model with this inverter

FR-F700(P)
V/F control
Simple magnetic flux vector control
PM motor control
400 Hz
Turn the X14 signal ON to enable PID
control.
Turn the CS signal ON to enable restart.
Pr. 186 "CS terminal function selection"
initial value "6"
Input from the terminal AU (the function of
the terminal AU is switched by a switch.)
B connector
Terminals R/L1, S/L2, T/L3, U, V, W: Same for all capacities
Terminals P/+, N/-, P1:
Same except for the 400 V class 01800(75K)
(FR-F740(P)-01800(75K): M10, FR-F840-01800(75K): M8)
Screws for earthing (grounding):
Same except for the 200 V class 03160(75K)
(FR-F720(P)-03160(75K): M10, FR-F820-03160(75K): M8)
Removable terminal block (screw type)
The FR-F800's I/O terminals have better response level than the FR-F700(P)'s terminals. By
setting Pr. 289 "Inverter output terminal filter" and Pr. 699 "Input terminal filter," the
terminal response level can be compatible with that of FR-F700(P). Set to approximately
5 to 8 ms and adjust the setting according to the system.
FR-DU07 (4-digit LED)
FR-PU07
Dedicated plug-in options (not interchangeable)
One connector (FR-F700P, FR-F700-CHT)
Two connectors (FR-F700-NA/EC)
Connected to the connector 1.
(FR-F700P, FR-F700-CHT)
Connected to the connector 2.
(FR-F700-NA/EC)
For standard models, installation size is compatible for all capacities.
(Replacement between the same capacities does not require new mounting holes.)
However, for the 200 V class 03160(75K), the installation interchange attachment
(FR-F8AT) is required.)
For separated converter types, installation size is not compatible. (New mounting
holes are required.)
Differences between FR-F700(P) and FR-F800 (1)
FR-F800
V/F control
Advanced magnetic flux vector control
PM motor control
(IPM motor/SPM motor)
USB host function
Safety stop function
etc.
590 Hz
The X14 signal does not need to be
assigned. (PID control is available by the
Pr. 128 setting.)
CS signal assignment not required. (Restart
is enabled with the Pr. 57 setting only.)
Pr. 186 "CS terminal function selection"
initial value "9999"
Input from the terminal 2. (The function of
the terminal 2 is switched by the Pr. 561
setting.)
Mini B connector
Removable terminal block (spring clamp
type)
FR-DU08 (5-digit LED)
FR-LU08 (LCD)
FR-PU07 (Some functions, such as
parameter copy, are unavailable.)
FR-DU07 is not supported.
Three connectors
Connected to the connector 1
A - 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents