Mitsubishi Electric FR-F820-00077 Instruction Manual page 185

Fr-f800 series
Hide thumbs Also See for FR-F820-00077:
Table of Contents

Advertisement

Parameters
Pr.
Pr.
Name
group
578
A400
Auxiliary motor operation selection
579
A401
Motor connection function selection
580
A402
MC switching interlock time
581
A403
Start waiting time
Auxiliary motor connection-time
582
A404
deceleration time
Auxiliary motor disconnection-time
583
A405
acceleration time
584
A406
Auxiliary motor 1 starting frequency
585
A407
Auxiliary motor 2 starting frequency
586
A408
Auxiliary motor 3 starting frequency
587
A409
Auxiliary motor 1 stopping frequency
588
A410
Auxiliary motor 2 stopping frequency
589
A411
Auxiliary motor 3 stopping frequency
590
A412
Auxiliary motor start detection time
591
A413
Auxiliary motor stop detection time
592
A300
Traverse function selection
593
A301
Maximum amplitude amount
Amplitude compensation amount
594
A302
during deceleration
Amplitude compensation amount
595
A303
during acceleration
596
A304
Amplitude acceleration time
597
A305
Amplitude deceleration time
H102
Undervoltage level
598
599
T721
X10 terminal input selection
600
H001
First free thermal reduction frequency 1
601
H002
First free thermal reduction ratio 1
602
H003
First free thermal reduction frequency 2
603
H004
First free thermal reduction ratio 2
604
H005
First free thermal reduction frequency 3
Power failure stop external signal input
606
T722
selection
607
H006
Motor permissible load level
608
H016
Second motor permissible load level
609
A624
PID set point/deviation input selection
610
A625
PID measured value input selection
611
F003
Acceleration time at a restart
653
G410
Speed smoothing control
654
G411
Speed smoothing cutoff frequency
Tab. 5-2:
Parameter overview (by number) (12)
FR-F800
Minimum
Setting range
setting
increments
0 to 3
1
0 to 3
1
0 to 100 s
0.1 s
0 to 100 s
0.1 s
0 to 3600 s, 9999
0.1 s
0 to 3600 s, 9999
0.1 s
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 3600 s
0.1 s
0 to 3600 s
0.1 s
0 to 2
1
0 to 25%
0.1%
0 to 50%
0.1%
0 to 50%
0.1%
0.1 to 3600 s
0.1 s
0.1 to 3600 s
0.1 s
350 to 430 V, 9999
0.1 V
0, 1
1
0 to 590 Hz, 9999
0.01 Hz
1 to 100%
1%
0 to 590 Hz, 9999
0.01 Hz
1 to 100%
1%
0 to 590 Hz, 9999
0.01 Hz
0, 1
1
110 to 250%
1%
110 to 250%, 9999
1%
1 to 5
1
1 to 5, 101 to 105
1
0 to 3600 s, 9999
0.1 s
0 to 200%
0.1%
0 to 120 Hz
0.01 Hz
Parameter List
Initial value
Refer
to page
FM
CA
0
5-392
0
5-392
1 s
5-392
1 s
5-392
1 s
5-392
1 s
5-392
60 Hz
50 HZ
5-392
60 Hz
50 HZ
5-392
60 Hz
50 HZ
5-392
0 Hz
5-392
0 Hz
5-392
0 Hz
5-392
5 s
5-392
5 s
5-392
0
5-346
10%
5-346
10%
5-346
10%
5-346
5 s
5-346
5 s
5-346
9999
5-161
0
5-552
1
9999
5-150
100%
5-150
9999
5-150
100%
5-150
9999
5-150
1
5-432
150%
5-150
9999
5-150
2
5-353
3
5-353
5-415,
9999
5-423
0%
5-567
20 Hz
5-567
5 - 13