Mitsubishi Electric FR-F820-00077 Instruction Manual page 786

Fr-f800 series
Hide thumbs Also See for FR-F820-00077:
Table of Contents

Advertisement

Ethernet communication (FR-F800-E)
– Remote register
Description
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01 Hz increments)
RWwn+2
H00 (arbitrary)
RWwn+3
Tab. 5-333:
Remote registers (write)
The above 8 bit is always H00 even if a value other than H00 is set.
"n" indicates a value determined by the station number setting.
● When Pr. 544 = "1" (compatible with CC-Link Ver.1)
– Remote I/O (32 points)
Same as when Pr. 544 = 0 (refer to page 5-613).
– Remote register
Description
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01 Hz increments)
Link parameter
RWwn+2
extended setting
RWwn+3
Tab. 5-335:
Remote registers (write)
"n" indicates a value determined by the station number setting.
● When Pr. 544 = "12" (compatible with the double setting of CC-Link Ver.2)
– Remote I/O (32 points)
Same as when Pr. 544 = 0 (refer to page 5-613).
– Remote register
Description
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01 Hz increments)
Link parameter
RWwn+2
extended setting
RWwn+3
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
Tab. 5-337:
Remote registers (write)
"n" indicates a value determined by the station number setting.
5 - 614
Refer to
Lower 8 bits
Monitor code 1
Instruction code
Write data
Refer to
Lower 8 bits
Monitor code 1
Instruction code
Write data
Refer to
Lower 8 bits
Monitor code 1
Instruction code
Write data
Address
page
Upper 8 bits
5-619
RWrn
5-619
RWrn+1
RWrn+2
5-619
RWrn+3
5-619
Tab. 5-334:
Address
page
Upper 8 bits
5-619
RWrn
5-619
RWrn+1
RWrn+2
5-619
RWrn+3
5-619
Tab. 5-336:
Address
page
Upper 8 bits
5-619
RWrn
5-619
RWrn+1
5-619
RWrn+2
RWrn+3
5-619
RWrn+4
5-619
5-619
RWrn+5
5-619
RWrn+6
5-619
RWrn+7
Tab. 5-338:
Description
Lower 8 bits
First monitor value
Second monitor value
Reply code
Read data
Remote registers (read)
Description
Lower 8 bits
First monitor value
Second monitor value
Reply code 2
Reply code 1
Read data
Remote registers (read)
Description
Lower 8 bits
First monitor value
Second monitor value
Reply code 2
Reply code 1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Remote registers (read)
Parameters
Refer to
page
5-620
5-620
5-620
5-620
Refer to
page
5-620
5-620
5-620
5-620
Refer to
page
5-620
5-620
5-620
5-620
5-620
5-620
5-620
5-620

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents