(N) Operation via communication and its settings
● Analog value
Object
identifier
1
2
3
6
8
14
17
20
23
25
52
54
67
92
94
95
200
201
202
203
300
310
311
312
320
Tab. 5-267: Object assignment for analog values (1)
5 - 512
Present value
Object name
access type
Output
R
frequency
Output current
R
Output voltage
R
Running speed
R
Converter
R
output voltage
Output power
R
Load meter
R
Cumulative
energization
R
time
Actual operation
R
time
Cumulative
R
power
PID set point
R
PID deviation
R
PID measured
R
value 2
Second PID set
R
point
Second PID
R
deviation
Second PID
measured value
R
2
Alarm history 1
R
Alarm history 2
R
Alarm history 3
R
Alarm history 4
R
C
Speed scale
PID set point
C
CMD
PID measured
C
value CMD
PID deviation
C
CMD
Second PID set
C
point CMD
Description
Represents the output frequency monitor.
Represents the output current monitor.
Represents the output voltage monitor.
Represents the running speed monitor.
Represents the converter output voltage
monitor.
Represents the output power monitor.
Represents the load meter monitor.
Represents the cumulative energization time
monitor.
Represents the actual operation time monitor.
Represents the cumulative power monitor.
Represents the PID set point monitor.
Represents the PID deviation monitor. (Minus
display is available with reference to 0%, 0.1%
increment)
Represents the PID measured value 2 monitor.
Represents the second PID set point monitor.
Represents the second PID deviation monitor.
(Minus display is available with reference to
0%, in 0.1% increment.)
Represents the second PID measured value 2
monitor.
Represents the fault history 1 (the latest fault)
monitor.
Represents the fault history 2 (second fault in
past) monitor.
Represents the fault history 3 (third fault in
past) monitor.
Represents the fault history 4 (fourth fault in
past) monitor.
Controls the ratio to the frequency command.
(Setting range: 0.00 to 100.00)
(refer to page 5-509)
Set the PID action set point.
This object is the PID set point during PID
operation if Pr. 128 = "60 or 61".
(Setting range: 0.00 to 100.0)
Set the PID measured value.
This object is the PID measured value during
PID operation if Pr. 128 = "60 or 61".
(Setting range: 0.00 to 100.0)
Set the PID deviation (0.01 increment). This
object is the deviation during PID operation if
Pr. 128 = "50 or 51".
(Setting range: -100.00 to 100.00)
Set the second PID action set point.
This object is the set point during PID
operation if Pr. 753 = "60 or 61". (Setting range:
0.00 to 100.00)
Parameters
Unit
hertz (27)
amperes (3)
volts (5)
revolution-per-
minute (104)
volts (5)
kilowatts (48)
percent (98)
hours (71)
hours (71)
kilowatt-
hours (19)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
no-units (95)
percent (98)
no-units (95)
no-units (95)
percent (98)
no-units (95)