(A) Application parameters
Set the load characteristics fault detection function. When the function is disabled, a trigger does
not occur. (Refer to page 5-189.)
The output signal can be used as a trigger if the signal is not assigned to a terminal.
When the automatic restart after instantaneous power failure is set for every start, or when the
online auto tuning is enabled, cleaning is started upon completion of the set operations.
While the self power management is enabled, the start trigger is disabled.
● Convert a bit image (binary) of the trigger factor into a decimal value, and set the value in Pr. 1471.
Decimal
15
14
13
12
11
10
: Trigger enabled, ×: Trigger disabled
Tab. 5-165: Settings of Pr. 1471
Fig. 5-157:
● Turning ON of X98 signal can be used as a trigger to start the cleaning operation. For the X98
signal input, set "98" in any of Pr. 178 to Pr. 189 to assign the function.
5 - 350
Pr. 1471
Binary
1111
1110
1101
1100
1011
1010
9
1001
8
1000
7
0111
6
0110
5
0101
4
0100
3
0011
2
0010
1
0001
0
0000
bit
15
7
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1
Pr. 1471 setting
Set the decimal converted value of the bit image.
Bit 0 to 3 of Pr. 1471 setting
bit 3
bit 2
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
0
bit 0 Start trigger
bit 1 Output current trigger
bit 2 PID upper/lower limit trigger
bit 3 Load warning trigger
Parameters
bit 1
bit 0
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
I003038E