Parameters
Pr.
Pr.
Name
group
Regeneration avoidance operation
882
G120
selection
Regeneration avoidance operation
883
G121
level
Regeneration avoidance at
884
G122
deceleration detection sensitivity
Regeneration avoidance compensation
885
G123
frequency limit value
886
G124
Regeneration avoidance voltage gain
888
E420
Free parameter 1
889
E421
Free parameter 2
Cumulative power monitor digit shifted
891
M023
times
892
M200
Load factor
Energy saving monitor reference
893
M201
(motor capacity)
Control selection during commercial
894
M202
power-supply operation
895
M203
Power saving rate reference value
896
M204
Power unit cost
897
M205
Power saving monitor average time
898
M206
Power saving cumulative monitor clear
899
M207
Operation time rate (estimated value)
Tab. 5-2:
Parameter overview (by number) (16)
FR-F800
Minimum
Setting range
setting
increments
0 to 2
1
300 to 800 V
0.1V
0 to 5
1
0 to 590 Hz, 9999
0.01 Hz
0 to 200%
0.1%
0 to 9999
1
0 to 9999
1
0 to 4, 9999
1
30 to 150%
0.1%
0.1 to 55 kW
0.01 kW
0 to 3600 kW
0.1 kW
0, 1, 2, 3
1
0, 1, 9999
1
0 to 500, 9999
0.01
0,1 to 1000 h, 9999
1 h
0, 1, 10, 9999
1
0 to 100%, 9999
0.1%
Parameter List
Initial value
Refer
to page
FM
CA
0
5-560
DC 380 V
5-560
DC 760 V
0
5-560
6 Hz
5-560
100%
5-560
9999
5-80
9999
5-80
5-198,
9999
5-224
100%
5-224
Inverter rated
5-224
capacity
0
5-224
9999
5-224
9999
5-224
9999
5-224
9999
5-224
9999
5-224
5 - 17