Parameters
PM parameter initialization list
● The parameter settings in the following table are changed to the settings required to perform PM
motor control by selecting PM motor control with the IPM parameter initialization mode on the
operation panel or with Pr. 998 "PM parameter initialization".
● Performing parameter clear or all parameter clear sets back the parameter settings to the settings
required to drive an induction motor.
Pr.
Name
Pr. 998
1
Maximum frequency
Multi-speed setting
4
(high speed)
Electronic thermal O/L
9
relay
13
Starting frequency
15
Jog frequency
High speed maximum
18
frequency
Acceleration/
20
deceleration reference
frequency
Stall prevention
22
operation level
37
Speed display
Frequency monitoring
55
reference
Current monitoring
56
reference
71
Applied motor
80
Motor capacity
81
Number of motor poles
84
Rated motor frequency
125
Terminal 2 frequency
(903)
setting gain frequency
126
Terminal 4 frequency
(905)
setting gain frequency
Speed setting
144
switchover
Soft-PWM operation
240
selection
Subtraction starting
263
frequency
Power failure
266
deceleration time
switchover frequency
Tab. 5-21:
PM parameter initialization list (1)
FR-F800
Induction motor
(rotations per minute)
0
(initial value)
12
FM
CA
120 Hz
Maximum motor
rotations per minute
60 Hz
Rated motor
60 Hz
50 Hz
rotations per minute
Rated motor current
Inverter rated current
(Refer to page 8-4.)
Minimum rotations
0.5 Hz
per minute
Minimum rotations
5 Hz
per minute
120 Hz
Maximum motor
rotations per minute
60 Hz
Rated motor
60 Hz
50 Hz
rotations per minute
120%
110%
0
Rated motor
60 Hz
50 Hz
rotations per minute
Rated motor current
Inverter rated current
(Refer to page 8-4.)
0
210
9999
Inverter capacity
Number of motor
9999
poles
Rated motor
rotations per minute
9999
Rated motor
60 Hz
50 Hz
rotations per minute
Rated motor
60 Hz
50 Hz
rotations per minute
Number of motor
4
poles + 100
1
Rated motor
60 Hz
50 Hz
rotations per minute
Rated motor
60 Hz
50 Hz
rotations per minute
Setting
PM motor
PM motor (frequency)
8009
14
112
9009
Maximum
motor
Maximum motor
frequency
frequency
Rated motor
Pr. 84
frequency
Rated motor current
(Refer to page 8-4.)
Pr. 84 ×
Minimum frequency
10%
Pr. 84 ×
Minimum frequency
10%
Maximum motor
frequency
Rated motor
Pr. 84
frequency
Short-time motor torque
0
Rated motor
Pr. 84
frequency
Rated motor current
Pr. 859
(Refer to page 8-4.)
240
210
Inverter capacity
Number of motor
poles
Rated motor
frequency
Rated motor
Pr. 84
frequency
Rated motor
Pr. 84
frequency
Pr. 81
Number of motor
+100
poles
0
Rated motor
Pr. 84
frequency
Rated motor
Pr. 84
frequency
Control method
Setting increments
12,14,
8109
114
8009,
9109
9009
Maximum
motor
frequency 1 r/min
Pr. 84
1 r/min
0.01 A
0.1 A
Pr. 84 ×
1 r/min
10%
Pr. 84 ×
1 r/min
10%
1 r/min
Pr. 84
1 r/min
0.1%
1
Pr. 84
1 r/min
0.01 A
Pr. 859
0.1 A
1
240
0.01 kW
0.1 kW
1
1 r/min
Pr. 84
1 r/min
Pr. 84
1 r/min
Pr. 81
1
1
Pr. 84
1 r/min
Pr. 84
1 r/min
0,
112,114,
8109,
9109
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
5 - 51