Parameters
Pr.
Pr.
Name
group
414
A800
PLC function operation selection
415
A801
Inverter operation lock mode setting
416
A802
Pre-scale function selection
417
A803
Pre-scale setting value
450
C200
Second applied motor
453
C201
Second motor capacity
454
C202
Number of second motor poles
455
C225
Second motor excitation current
456
C204
Rated second motor voltage
457
C205
Rated second motor frequency
458
C220
Second motor constant (R1)
459
C221
Second motor constant (R2)
Second motor constant (L1) /
460
C222
d-axis inductance (Ld)
Second motor constant (L2) /
461
C223
q-axis inductance (Lq)
462
C224
Second motor constant (X)
Second motor auto tuning setting/
463
C210
status
495
M500
Remote output selection
496
M501
Remote output data 1
497
M502
Remote output data 2
498
A804
PLC function flash memory clear
Communication error execution
N011
500
waiting time
Communication error occurrence count
N012
501
display
Stop mode selection at communication
502
N013
error
503
E710
Maintenance timer 1
Maintenance timer 1 warning output
504
E711
set time
505
M001
Speed setting reference
Tab. 5-2:
Parameter overview (by number) (10)
FR-F800
Minimum
Setting range
setting
increments
0 to 2
0, 1
0 to 5
0 to 32767
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 40, 43, 44, 50, 53,
54, 70, 73, 74, 210, 213,
214, 240, 243, 244, 8093,
8094, 9090, 9093, 9094,
9999
0.4 to 55 kW, 9999
0.01 kW
0 to 3600 kW, 9999
0.1 kW
2, 4, 6, 8, 10, 12, 9999
0 to 500 A, 9999
0.01 A
0 to 3600 A, 9999
0.1 A
0 to 1000 V
10 to 400 Hz, 9999
0.01 Hz
0 to 50 Ω, 9999
0.001 Ω
0 to 400 mΩ, 9999
0.01 mΩ
0 to 50 Ω, 9999
0.001 Ω
0 to 400 mΩ, 9999
0.01 mΩ
0 to 6000 mH, 9999
0.1 mH
0 to 400 mH, 9999
0.01 mH
0 to 6000 mH, 9999
0.1 mH
0 to 400 mH, 9999
0.01 mH
0.1%
0 to 100%, 9999
0.01%
0, 1, 11, 101
0, 1, 10, 11
0 to 4095
0 to 4095
0, 9696
(0 to 9999)
0 to 999.8 s
0
0 to 4
0 (1 to 9998)
0 to 9998, 9999
1 to 590 Hz
0.01 Hz
Parameter List
Initial value
Refer
to page
FM
CA
1
0
5-439
1
0
5-439
1
0
5-439
1
1
5-439
1
9999
5-297
5-303,
9999
5-316
5-303,
1
9999
5-316
9999
5-303
200 V
5-303,
0.1 V
5-316
400 V
5-303,
9999
5-316
5-303,
9999
5-316,
5-426
9999
5-303
5-303,
9999
5-316
5-303,
9999
5-316
9999
5-303
5-303,
1
0
5-316,
5-426
1
0
5-247
1
0
5-247
1
0
5-247
1
0
5-439
0.1 s
0 s
5-459
1
0
5-459
1
0
5-459
1
0
5-95
1
9999
5-95
60 Hz
50 Hz
5-196
5 - 11