Mitsubishi Electric FR-F820-00077 Instruction Manual page 407

Fr-f800 series
Hide thumbs Also See for FR-F820-00077:
Table of Contents

Advertisement

Parameters
Setting
Positive
logic
94
95
96
98
99
200
201
202
203
204
205
206
207
208
211
212
213
215
Tab. 5-101: Output terminal function assignment (4)
FR-F800
Signal
Function
Negative
name
logic
194
ALM2 Fault output 2
195
Y95
Maintenance timer signal
196
REM
Remote output
198
LF
Alarm
199
ALM
Fault
300
FDN2 Second PID lower limit
301
FUP2
Second PID upper limit
Second PID forward/
302
RL2
reverse rotation output
Second During PID
303
PID2
control activated
During second PID
304
SLEEP2
output shutoff
Second PID deviation
305
Y205
limit
Cooling fan operation
306
Y206
command signal
Control circuit
307
Y207
temperature signal
308
PS
PU stopped signal
Upper limit warning
311
LUP
detection
Lower limit warning
312
LDN
detection
During load
313
Y213
characteristics
measurement
315
Y215
During cleaning
(M) Monitor display and monitor output signal
Operation
Output when the inverter's protective
function is activated to stop the output
(at fault occurrence).
The signal output continues even during
an inverter reset, and the signal output
stops after the reset release.
Output when Pr. 503 reaches the Pr. 504
setting or higher.
Output via terminals when certain
parameters are set.
Output when an alarm (fan fault or
communication error warning) occurs.
Output when the inverter's protective
function is activated to stop the output
(at fault occurrence). The signal output is
stopped after a reset.
Output when the value is lower than the
lower limit of second PID control.
Output when the value is higher than the
upper limit of second PID control.
Output during forward rotation under
second PID control.
Output during second PID control.
Output during second PID output
suspension function operation.
Output when the absolute deviation
value during second PID control exceeds
the limit value.
Output when the cooling fan operation is
commanded.
Output when the temperature of the
control circuit board reaches the
detection level or higher.
Output while the PU is stopped.
Output when the load fault upper limit
warning is detected.
Output when the load fault lower limit
warning is detected.
Output during measurement of the load
characteristics.
Output during operation of the cleaning
function.
Related
Refer to
parameter
page
5-239
Pr. 503, Pr. 504
5-95
Pr. 495 to
5-247
Pr. 497
5-160,
Pr. 121, Pr. 244
5-459
5-239
Pr. 753 to
Pr. 758
5-353
Pr. 753 to
Pr. 758, Pr. 1147
to Pr. 1149
Pr. 753 to
Pr. 758,
Pr. 1145,
Pr. 1146
Pr. 244
5-160
Pr. 663
Pr. 75
5-63
Pr. 1480 to
5-189
Pr. 1492
Pr. 1469 to
5-348
Pr. 1479
5 - 235