Configuring the OAM PDU Threshold

Copyright © 2016, Juniper Networks, Inc.
To configure the sending interval, include the
oam ethernet link-fault-management interface interface-name]
[edit protocol oam ethernet link-fault-management interface interface-name]
pdu-interval
interval;
The periodic OAM PDU interval range is from 100 through 1000 milliseconds. The default
sending interval is 1000 milliseconds.
pdu-interval on page 63
IEEE 802.3ah OAM Link-Fault Management Overview on page 3
Configuring IEEE 802.3ah OAM Link-Fault Management on page 5
Enabling IEEE 802.3ah OAM Support on page 6
Configuring Link Discovery on page 16
Configuring the OAM PDU Threshold on page 7
Configuring Threshold Values for Local Fault Events on an Interface on page 17
Disabling the Sending of Link Event TLVs on page 18
Detecting Remote Faults on page 18
Configuring an OAM Action Profile on page 8
Specifying the Actions to Be Taken for Link-Fault Management Events on page 19
Monitoring the Loss of Link Adjacency on page 12
Monitoring Protocol Status on page 13
Configuring Threshold Values for Fault Events in an Action Profile on page 10
Applying an Action Profile on page 10
Setting a Remote Interface into Loopback Mode on page 11
Enabling Remote Loopback Support on the Local Interface on page 15
Example: Configuring IEEE 802.3ah OAM Support on an Interface on page 21
Ethernet Interfaces Feature Guide for Routing Devices
You can specify the number of OAM PDUs that an interface can miss before the link
between peers is considered down.
To configure the number of PDUs that can be missed from the peer, include the
statement at the
pdu-threshold
interface interface-name]
hierarchy level:
[edit protocol oam ethernet link-fault-management interface interface-name]
pdu-threshold
threshold-value;
The threshold value range is from 3 through 10. The default is three PDUs.