frame-period

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
Copyright © 2016, Juniper Networks, Inc.
Chapter 5: Configuration Statements: Ethernet OAM Link Fault Management
frame-period count;
[edit protocols oam
ethernet link-fault-management action-profile event
[edit protocols oam
link-fault-management interface
Statement introduced in Junos OS Release 8.4.
Threshold for sending frame period error events or taking the action specified in the action
profile.
A frame error is any frame error on the underlying physical layer. The frame period
threshold is reached when the number of frame errors reaches the configured value within
the period window. The default period window is the number of minimum-size frames
that can be transmitted on the underlying physical layer in 1 second. The window is not
configurable.
—Threshold count for frame period error events.
count
Range: 0 through 100
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Configuring Threshold Values for Local Fault Events on an Interface on page 17
Configuring Threshold Values for Fault Events in an Action Profile on page 10
link-event-rate],