Juniper EX9200 Features Manual page 146

Network management and monitoring feature guide
Hide thumbs Also See for EX9200:
Table of Contents

Advertisement

Network Management and Monitoring Feature Guide for EX9200 Switches
Table 9: show interfaces Gigabit Ethernet Output Fields (continued)
Field Name
Field Description
(10-Gigabit Ethernet interfaces, WAN PHY mode) Active alarms and defects,
WIS path
plus counts of specific SONET errors with detailed information.
Seconds
Count
State
Subfields are:
BIP-B3
REI-P
LOP-P
AIS-P
RDI-P
UNEQ-P
PLM-P
ES-P
SES-P
UAS-P
SES-PFE
UAS-PFE
130
—Number of seconds the defect has been active.
—Number of times that the defect has gone from inactive to active.
—State of the error. Any state other than
—Bit interleaved parity for SONET section overhead
—Remote error indication
—Loss of pointer (path)
—Path alarm indication signal
—Path remote defect indication
—Path unequipped
—Path payload label mismatch
—Errored seconds (near-end STS path)
—Severely errored seconds (near-end STS path)
—Unavailable seconds (near-end STS path)
—Severely errored seconds (far-end STS path)
—Unavailable seconds (far-end STS path)
indicates a problem.
OK