Network Management and Monitoring Feature Guide for EX9200 Switches

pdu-threshold

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation

protocol-down

Syntax
Hierarchy Level
Release Information
Description
Required Privilege
Level
Related
Documentation
64
pdu-threshold threshold-value;
[edit protocols oam
ethernet link-fault-management interface
Statement introduced in Junos OS Release 8.2.
For Ethernet interfaces on EX Series switches and M320, M120, MX Series, and T Series
routers, specify the number of OAM PDUs to miss before an error is logged. Used for IEEE
802.3ah Operation, Administration, and Management (OAM) support.
threshold-value
—The number of PDUs missed before declaring the peer lost.
Range: 3 through 10 PDUs
Default: 3 PDUs
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Configuring the OAM PDU Threshold on page 7
protocol-down;
[edit protocols oam
ethernet link-fault-management action-profile
Statement introduced in Junos OS Release 8.5.
Upper layer indication of protocol down event. When the
included, the protocol down event triggers the action specified under the
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Configuring an OAM Action Profile on page 8
interface-name]
event]
protocol-down
statement is
statement.
action