o3: Copy Function

No.
(Addr.
Name
Hex)
o3-01
Copy Function Selection
(515)
o3-02
Copy Allowed Selection
(516)
u

o4: Maintenance Monitor Settings

No.
(Addr.
Name
Hex)
o4-01
Cumulative Operation Time
(50B)
Setting
o4-02
Cumulative Operation Time
(50C)
Selection
o4-03
Cooling Fan Operation Time
(50E)
Setting
o4-05
Capacitor Maintenance
(51D)
Setting
o4-07
DC Bus Pre-Charge Relay
(523)
Maintenance Setting
o4-09
IGBT Maintenance Setting
(525)
o4-11
U2, U3 Initialization
(510)
o4-12
kWh Monitor Initialization
(512)
o4-13
Number of Run Commands
(528)
Counter Initialization
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Description
0: No action
1: Read parameters from the drive, saving them onto the digital operator.
2: Copy parameters from the digital operator, writing them to the drive.
3: Verify parameter settings on the drive to check if they match the data saved
on the operator.
0: Read operation prohibited
1: Read operation allowed
Description
Sets the value for the cumulative operation time of the drive in units of 10 h. Default: 0 h
0: Logs power-on time
1: Logs operation time when the drive output is active (output operation time).
Sets the value of the fan operation time monitor U4-03 in units of 10 h.
Sets the value of the Maintenance Monitor for the capacitors. See U4-05 to
check when the capacitors may need to be replaced.
Sets the value of the Maintenance Monitor for the soft charge bypass relay.
See U4-06 to check when the bypass relay may need to be replaced.
Sets the value of the Maintenance Monitor for the IGBTs. See U4-07 for IGBT
replacement times.
0: U2-oo and U3-oo monitor data is not reset when the drive is initialized
(A1-03).
1: U2-oo and U3-oo monitor data is reset when the drive is initialized
(A1-03).
0: U4-10 and U4-11 monitor data is not reset when the drive is initialized
(A1-03).
1: U4-10 and U4-11 monitor data is reset when the drive is initialized (A1-03).
0: Number of Run commands counter is not reset when the drive is initialized
(A1-03).
1: Number of Run commands counter is reset when the drive is initialized
(A1-03).
B.10 o: Operator-Related Settings
Values
Default: 0
Range: 0 to 3
Default: 0
Range: 0, 1
Values
Min.: 0
Max.: 9999
Default: 0
Range: 0, 1
Default: 0 h
Min.: 0
Max.: 9999
Default: 0%
Min.: 0
Max.: 150
Default: 0%
Min.: 0
Max.: 150
Default: 0%
Min.: 0
Max.: 150
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1