E3: V/F Pattern For Motor 2 - YASKAWA A1000 Technical Manual

Hide thumbs Also See for A1000:
Table of Contents

Advertisement

u

E3: V/f Pattern for Motor 2

These parameters are hidden when a PM motor control mode has been selected for motor 1 (A1-02 = 5, 6, 7).
No.
(Addr.
Name
Hex)
E3-01
Motor 2 Control Mode
(319)
Selection
E3-04
Motor 2 Maximum Output
(31A)
Frequency
E3-05
Motor 2 Maximum Voltage
(31B)
E3-06
Motor 2 Base Frequency
(31C)
E3-07
Motor 2 Mid Output
(31D)
Frequency
E3-08
Motor 2 Mid Output
(31E)
Frequency Voltage
E3-09
Motor 2 Minimum Output
(31F)
Frequency
E3-10
Motor 2 Minimum Output
(320)
Frequency Voltage
E3-11
Motor 2 Mid Output
(345)
Frequency 2
<3>
E3-12
Motor 2 Mid Output
(346)
Frequency Voltage 2
<3>
E3-13
Motor 2 Base Voltage
(347)
<1> Default setting is dependent on E3-01, Motor 2 Control Mode Selection. The value shown here is for V/f Control (0).
<2> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.
<3> Ignored when E3-11, Motor 2 Mid Output Frequency 2, and E3-12, Motor 2 Mid Output Frequency Voltage 2, are set to 0.
<4> The setting range is 0.0 to 66.0 in AOLV/PM.
<5> When Auto-Tuning is performed, E1-13 and E1-05 will be set to the same value.
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Description
0: V/f Control
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E3-07 and E3-09. In
this case, the setting for E3-08 will be disregarded. Ensure that the four
frequencies are set according to these rules or an oPE10 fault will occur:
E3-09 ≤ E3-07 < E3-06 ≤ E3-11 ≤ E3-04
Output Voltage (V)
E3-05
E3-12
E3-13
E3-08
E3-10
E3-09
Note: E3-07 and E3-08 are only available in the following control modes:
V/f, V/f w/PG and OLV.
E3-07 E3-06 E3-11 E3-04
Frequency (Hz)
B.5 E: Motor Parameters
Values
Page
Default: 0
Range: 0 to 3
<1>
Default:
Min.: 40.0
Max.: 400.0
<1>
Default:
Min.: 0.0 V
<2>
Max.: 255.0 V
<1>
Default:
Min.: 0.0
Max.: E3-04
<1>
Default:
Min: 0.0
Max: E3-04
<1>
Default:
Min: 0.0 V
<2>
Max: 255.0 V
<1>
Default:
Min.: 0.0
Max.: E3-04
<1>
Default:
Min: 0.0 V
<2>
Max: 255.0 V
Default: 0.0
Min.: 0.0
<4>
Max.: E3-04
Default: 0.0 V
Min.: 0.0
<2>
Max.: 255.0
<5>
Default: 0.0 V
Min.: 0.0
<2>
Max.: 255.0
195
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents