C.2 UL and CSA Standards
u

UL Standards Compliance

The UL/cUL mark applies to products in the United States and Canada. It indicates that UL has performed product testing and
evaluation, and determined that their stringent standards for product safety have been met. For a product to receive UL
certification, all components inside that product must also receive UL certification.
This drive is tested in accordance with UL standard UL508C and complies with UL requirements. The conditions described
below must be met to maintain compliance when using this drive in combination with other equipment:
n
Installation Area
Do not install the drive to an area greater than pollution degree 2 (UL standard).
n
Main Circuit Terminal Wiring
Yaskawa recommends using closed-loop crimp terminals on all drive models. UL/cUL approval requires the use of closed-
loop crimp terminals when wiring the drive main circuit terminals on models CIMR-Ao2A0110 to 2A0415 and 4A0058 to
4A1200. Use only the tools recommended by the terminal manufacturer for crimping.
Size on page 245
for closed-loop crimp terminal recommendations.
Closed-Loop Crimp Terminal Recommendations
Yaskawa recommends using closed-loop crimp terminals on all drive models. UL approval requires the use of crimp terminals
when wiring the drive main circuit terminals on models CIMR-Ao2A0110 to 2A0415 and 4A0058 to 4A1200. Use only
crimping tools as specified by the crimp terminal manufacturer. Yaskawa recommends crimp terminals made by JST and
Tokyo DIP (or equivalent) for the insulation cap.
Table C.4
matches the wire gauges and terminal screw sizes with Yaskawa-recommended crimp terminals, tools, and insulation
caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge and screw size for your drive
model. Place orders with a Yaskawa representative or the Yaskawa sales department.
The closed-loop crimp terminal sizes and values listed in
proper selections.
Terminal
Wire Gauge
Screws
2
2 mm
M4
14 AWG
M4
2
3.5 / 5.5 mm
12 / 10 AWG
M5
M4
8 mm
2
M5
8 AWG
M8
M4
M5
2
14 mm
M6
6 AWG
M8
M10
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Figure C.6 UL/cUL Mark
Table C.4
Table C.4 Closed-Loop Crimp Terminal Size
Crimp Terminal
Model Number
Machine No.
R2-4
YA-4
R5.5-4
YA-4
R5.5-5
YA-4
8-4
YA-4
R8-5
YA-4
R8-8
YA-4
14-NK4
YA-4
R14-5
YA-4
R14-6
YA-5
R14-8
YA-5
R14-10
YA-5
C.2 UL and CSA Standards
Refer to Closed-Loop Crimp Terminal
are Yaskawa recommendations. Refer to local codes for
Tool
Die Jaw
AD-900
AD-900
AD-900
AD-901
AD-901
AD-901
AD-902
AD-902
AD-952
AD-952
AD-952
Insulation
<1>
Cap
Code
Model No.
TP-003
100-054-028
TP-005
100-054-029
TP-005
100-054-030
TP-008
100-054-031
TP-008
100-054-032
TP-008
100-061-111
TP-014
100-054-033
TP-014
100-054-034
TP-014
100-051-261
TP-014
100-054-035
TP-014
100-061-112
245