A.2 Power Ratings
u

Three-Phase 200 V Class Drive Models CIMR-Ao2A0004 to 2A0030

Item
CIMR-Ao2A
Maximum Applicable Motor
<1>
Capacity (HP)
Input Current (A)
Rated Voltage
Rated Frequency
Input
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Input Power (kVA)
Rated Output Capacity
<4>
(kVA)
Rated Output Current (A)
Output
Overload Tolerance
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> DC is not available for UL/CE standards.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating..
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Table A.2 Power Ratings (Three-Phase 200 V Class)
0004
ND Rating
HD Rating
ND Rating
<2>
HD Rating
ND Rating
HD Rating
<5>
ND Rating
HD Rating
<5>
ND Rating
HD Rating
0006
0008
0.75
1
2
0.75
1
2
3.9
7.3
8.8
2.9
5.8
7
Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc
2.2
3.1
4.1
1.3
2.2
3.1
1.3
2.3
3
1.2
1.9
2.6
<6>
<6>
<6>
3.5
6
8
3.2
5
6.9
<6>
<6>
<6>
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
User adjustable between 1 and 15 kHz
Three-phase 200 to 240 V (proportional to input voltage)
400 Hz (user-set)
A.2 Power Ratings
Specification
0010
0012
0018
3
3
5
2
3
3
10.8
13.9
18.5
7.5
11
15.6
-15 to 10%
±5%
5.8
7.8
9.5
4.1
5.8
7.8
3.7
4.6
6.7
3
4.2
5.3
<6>
<6>
<6>
9.6
12
17.5
8
11
14
<6>
<6>
<6>
0021
0030
7.5
10
5
7.5
24
37
18.9
28
<3>
14
18
9.5
14
8
11.4
6.7
9.5
<6>
<6>
21
30
17.5
25
<6>
<6>
A