C2: S-Curve Characteristics; C3: Slip Compensation - YASKAWA A1000 Technical Manual

Hide thumbs Also See for A1000:
Table of Contents

Advertisement

u

C2: S-Curve Characteristics

No.
(Addr.
Name
Hex)
C2-01
S-Curve Characteristic at
(20B)
Accel Start
C2-02
S-Curve Characteristic at
(20C)
Accel End
C2-03
S-Curve Characteristic at
(20D)
Decel Start
C2-04
S-Curve Characteristic at
(20E)
Decel End
<1> Default setting is determined by parameter A1-02, Control Method Selection.
u

C3: Slip Compensation

No.
(Addr.
Name
Hex)
C3-01
(20F)
Slip Compensation Gain
C3-02
Slip Compensation Primary
(210)
Delay Time
C3-03
Slip Compensation Limit
(211)
Slip Compensation
C3-04
Selection during
(212)
Regeneration
C3-05
Output Voltage Limit
(213)
Operation Selection
Output Voltage Limit
C3-16
Operation Start Level
(261)
(Percentage Modulation)
Maximum Output Voltage
C3-17
Limit Level (Percentage
(262)
Modulation)
C3-18
Output Voltage Limit Level
(263)
C3-21
Motor 2 Slip Compensation
(33E)
Gain
C3-22
Motor 2 Slip Compensation
(241)
Primary Delay Time
C3-23
Motor 2 Slip Compensation
(242)
Limit
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Description
The S-curve can be controlled at the four points shown below.
Run Command
Output Frequency
C2-01
Description
Sets the gain for the motor slip compensation function used for motor 1.
Adjusts the slip compensation function delay time used for motor 1.
Sets an upper limit for the slip compensation function as a percentage of motor
rated slip for motor 1 (E2-02).
0: Disabled.
1: Enabled above 6 Hz.
2: Enabled whenever slip compensation is possible.
0: Disabled.
1: Enabled. Automatically decreases motor flux when output voltage
saturation is reached.
Sets the output voltage limit operation start level (percentage modulation)
when C3-05 is enabled.
Note: This parameter is not available in models CIMR-Ao4A0930 and
4A1200.
Sets the output voltage limit operation determined by C3-18 (percentage
modulation) when C3-05 is enabled.
Note: This parameter is not available in models CIMR-Ao4A0930 and
4A1200.
Sets the maximum percentage of output voltage reduction when C3-05 is
enabled.
Note: This parameter is not available in models CIMR-Ao4A0930 and
4A1200.
Sets the slip compensation gain used for motor 2.
Sets the slip compensation delay time used for motor 2.
Sets the upper limit for the slip compensation function for motor 2. Set as a
percentage of the motor rated slip (E4-02).
ON
OFF
C2-02
C2-03
C2-04
Time
B.3 C: Tuning
Values
Page
<1>
Default: 0.20 s
Min.: 0.00
Max.: 10.00
Default: 0.20 s
Min.: 0.00
Max.: 10.00
Default: 0.20 s
Min.: 0.00
Max.: 10.00
Default: 0.00 s
Min.: 0.00
Max.: 10.00
Values
Page
<1>
Default:
Min.: 0.0
Max.: 2.5
<1>
Default:
Min.: 0 ms
Max.: 10000 ms
Default: 200%
Min.: 0
Max.: 250
Default: 0
Range: 0 to 2
Default: 0
Range: 0, 1
Default: 85.0%
Min.: 70.0
Max.: 90.0
Default: 90.0%
Min.: 85.0
Max.: 100.0
Default: 90.0%
Min.: 30.0
Max.: 100.0
<2>
Default:
Min.: 0.0
Max.: 2.5
<2>
Default:
Min.: 0 ms
Max.: 10000 ms
Default: 200%
Min.: 0
Max.: 250
185
B