Power Ratings - YASKAWA iQpump Micro CIMR-PW Series User Manual

Ac drive compact intelligent pump controller
Table of Contents

Advertisement

A.1 Power Ratings
A.1 Power Ratings
u
Single-Phase 200 V Class Drives
Single-Phase Drive Model
Maximum Motor Size Allowed kW (HP)
Input
Rated Output Capacity (kVA)
Output
Power Supply
Allowable Frequency Fluctuation
Harmonic Corrective
Actions
<1> Drives with single-phase power supply input will output three-phase power and cannot run a single-phase motor.
<2> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<3> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 230 V.
<5> DC is not available for UL standards.
308
Table A.1 Single-Phase 200 V Class Power Ratings
Item
<1>
<2>
<3>
Input Current (A)
Output Current (A)
Overload Tolerance
Carrier Frequency
Max Output Voltage (V)
Max Output Frequency (Hz)
Rated Voltage
Rated Frequency
Allowable Voltage Fluctuation
DC Link Choke
BV0006
1.1 (1)
13.8
<4>
2.3
6.0
120% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Single-phase power: 200 to 240 V
(both proportional to input voltage)
Single-phase power: 200 to 240 V 50/60 Hz
DC power supply: 270 to 340 V
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Specification
BV0010
BV0012
2.2 (3)
3.0 (3)
20.2
24.0
3.7
4.6
9.6
12.0
User-adjustable 2 to 15 kHz
400 Hz (user-adjustable)
<5>
-15 to 10%
±5%
Optional
BV0018
3.7 (5)
35.0
6.7
17.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents