Show Env - Cisco Catalyst 3750-X Command Reference Manual

Cisco ios release 15.2(1)e and later
Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands

show env

Use the show env user EXEC command to display fan, temperature, redundant power system (RPS)
availability, and power information for the switch or the switch stack.
Syntax Description
all
fan
power
power all
power switch
[switch-number]
rps
stack
[switch-number]
temperature
temperature
status
xps
Command Modes
User EXEC
Command History
Release
12.2(53)SE2
OL-29704-01
show env {all | fan | power [all | switch [switch-number]] | rps | stack [switch-number] |
temperature [status] | xps}
Display the fan and temperature environmental status and the status of the internal
power supplies and the RPS.
Display the switch fan status.
Display the switch internal power status.
(Optional) Display the status of all the internal power supplies in a standalone
switch when the command is entered on the switch or in all the stack members
when the command is entered on the stack master.
(Optional) Display the status of the internal power supplies for each switch in the
stack or for the specified switch. The range is 1 to 9, depending on the switch
member numbers in the stack.
These keywords are available only on Catalyst 3750-E switches.
Display whether a redundant power system is connected to a Catalyst 3750-E or
Catalyst 3750 switch in the stack as follows:
Catalyst 3750-E—Cisco Redundant Power System 2300, also referred to as
the RPS 2300.
Catalyst 3750 switch—the RPS 2300 or Cisco RPS 675 Redundant Power
System, also referred to as the RPS 675.
Catalyst 3750-X and 3560-X switches do not connect to redundant power
Note
systems.
Display all environmental status for each switch in the stack or for the specified
switch. The range is 1 to 9, depending on the switch member numbers in the stack.
This keyword is available only on stacking-capable switches.
Display the switch temperature status.
(Optional) Display the switch internal temperature (not the external temperature)
and the threshold values.
(Optional) Display information for the Cisco eXpandable Power System (XPS)
2200. See the show env xps command.
Modification
This command was introduced.
Catalyst 3750-X and 3560-X Switch Command Reference
show env
2-625

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3560-x

Table of Contents