Meridian Link/Customer Controlled Routing Installation And Upgrade Manual page 558

Meridian controlled routing installation and upgrade guide
Table of Contents

Advertisement

540 Chapter 19: Single Terminal Access
553-3202-210 Standard October 1998
Table 148
LD 17ÑConfigure MSDL port
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
NEW STA x
TTY
0-15
CTYP
MSDL
GRP
0
DNUM
0Ð15
ADMIN_
0
PORT
LANG
(ENG)
ADDITIONAL
P1, P2, P3
PORTS*
* If one of the ADDITIONAL PORTS must be deleted, type an ÒXÓ before
the port number (for example, XP2).
12
Verify the above configuration in LD 22.
13
Access LD 48 and type ENL STA x to enable the STA port.
14
Type STAT STA x to verify the status of the STA application.
Figure 301 shows STA 0 on port 0 (admin port) is enabled.
Comment
Create or change information in the
database
Configuration record data block
Add STA with a logical ID x (0-15)
Device number (MSDL SDI TTY)
Note: Use the same TTY number
you assigned to the ADAN prompt in
step 8.
Card type is MSDL (automatic
response)
Network Group Number (this prompt
only appears for Option 81 systems)
Device number; same as TTY
(automatic response)
Admin port number (automatic
response)
Language supported (automatic
response for Release 19)
The MSDL port(s) cabled to the SYS
CONS port