NT8D37 backplane cable rerouting for segment 2Ñto
accommodate the IPE Module in PE slots 8Ð11
With the cables located as shown in Table 67:
1
Leave cable K as is in slot position L8.
2
Remove cable M from the backplane and connect cable ends M-1,
M-2, and M-3 to slot positions L11-1, L11-2, and L11-3.
3
Move the M connector on the I/O panel to position N. Now the cable
designation is changed from M to N.
CAUTION
Risk of hardware damage
!
With this rerouting, the IPE Module can be used only in
PE slots 8Ð11. Also, when the IPE Module is not in PE
slots 8Ð11, PE slot 10 should not be used at all.
Note: Reroute the cable only in the segment where the IPE Module is
going to be installed. Do not reroute the cable in other segments.
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Chapter 9: Meridian Link/CCR interface cabling 207