Meridian Link/Customer Controlled Routing Installation And Upgrade Manual page 439

Meridian controlled routing installation and upgrade guide
Table of Contents

Advertisement

Chapter 14: Software installation, upgrade, and update procedures 421
Procedure 5: Load the operating system tape on an Application Module
with an MVME147 card (continued)
20
Type 1 and press [Return] to install the software.
The BOS installation procedure begins.
Figure 156
BOS installation, phase 1
BOS INSTALLATION PROCEDURE
Phase 1.
Identify Root And Usr File Systems Installation Disk Drive(s)
The BOS product supports root and usr file system installations
on the disk controllers listed below.
selection number, the second column is the name of the controller, and,
the third column is a brief description of the controller.
at the prompt the root file systemÕs installation disk controller type.
1
MVME147
The MVME147 CPU Processor/SCSI Controller
2
MVME167
The MVME167 CPU Processor/SCSI Controller
3
MVME323
The MVME323 ESDI Disk Controller
4
MVME327
The MVME327 SCSI Bus Controller
5
MVME328
The MVME328 SCSI Host Adapter
---> Enter a number, a name, the initial part of a name, or
? or <number>? for HELP, or q to QUIT [MVME167]:
21
When prompted to select the SBC card, type 1 and press [Return].
The system response is ÒSelected the ÔMVME147Õ controller type.Ó
Figure 157
Disk drive number prompt
---> Enter the root file systemÕs disk drive number
(00, 10, 20, 30, ?, q) [00]:
22
You are prompted to enter the root file systemÕs disk drive number.
Press [Return] to select the default disk drive number (00).
The disk drive selection list appears.
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
The first column is the controllerÕs
Identify