Chapter 12: Meridian 1 configuration for Meridian Link/CCR 301
Table 106
LD 17ÑConfigure ESDI port (Options 21Ð81) (continued)
Prompt
Response
CMS
x
SECU
YES
INTL
4
MCNT
400
CONF
DIR
CMS
<cr>
VSID
<cr>
VAS
<cr>
CSQI
(20)Ð255
CSQO
(20)Ð255
¥
¥
¥
REQ
END
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Comment
ESDI port number for this AML. This must
be the same as the port number defined at
the ADAN prompt.
Security for AML. Must be set to Yes.
Time interval (five-second increments) used
to determine overload conditions
Message count threshold for number of
messages per time interval (from INTL)
Direct link for this AML configuration
ESDI port number for CSL (0Ð15)
Maximum call registers for AML input
queues
Maximum call registers for AML output
queues
Set CSQI and CSQO equal to the number of
ACD agents or AST sets, or 50 whichever is
larger, but not more than 25 percent of the
total number of call registers (NCR prompt).
Press [Return] until the REQ prompt
appears
Either change more configuration data or
exit the overlay, saving changes to the
configuration record.
Ñ end Ñ