Configure ESDI or MSDL port (X11 Release 18 or later)

Option 11 ESDI configuration

Table 108
LD 17ÑConfigure ESDI port (Option 11)
Chapter 12: Meridian 1 configuration for Meridian Link/CCR 305
The IPE Module or the Application Module is connected to the Meridian 1
through a port on a QPC513 ESDI card (vintage G or later), NTAK02
SDI/DCH card (Option 11, IPE Module only), or NT6D80 MSDL card.
The port must have the Application Module Link (AML) identified
(VSID 0Ð15). Define the port and its characteristics by responding to the
following prompts in LD 17.
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
NEW AML x
CDNO
0Ð15
PORT
0Ð3
DES
LINK/CCR
BPS
19200
CLOK
INT
IADR
3
RADR
1
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Comment
Create or change information in the
database
Configuration record data block
Add AML on port x (VASID 0Ð15)
Serial Data Interface Card Number
Port number on SDI/DCH card
AML port designation (such as
ÒMeridian LinkÓ)
19,200 bps baud rate (19.2 kbps). The
AML (connection from SDI/DCH card
to the IPE Module) rate must match
the baud rate of link 0 on the IPE
Module.
Internal clock (this prompt only
appears for ESDI)
Individual address for the data-link
level-HDLC protocol
Remote address for the data-link level
HDLC protocol
ÐcontinuedÐ