256 Chapter 9: Meridian Link/CCR interface cabling

Installing Ethernet LAN support

553-3202-210 Standard October 1998

7
Power up the Application Module.
8
Define the Meridian Mail Link parameters using Procedure 15 in
Chapter 15, ÒLink configurationÓ in this guide.
Note: Return to Chapter 5, ÒHardware installation overviewÓ for the
next procedure. For more information on Meridian Mail, refer to
Chapter 13, ÒMeridian Mail configuration.Ó
Hardware and software requirements for installing Ethernet LAN support
are discussed in the ÒEthernet LAN-based PCÓ section in the Chapter 1,
ÒMeridian Link/CCR co-residencyÓ. However, you should be aware of the
following:
¥
All IPE Modules can provide Ethernet LAN support
¥
Application Modules can provide Ethernet LAN support only if they
have the following:
Ñ an MVME167-02 SBC card
Ñ an MVME712M transition card
Ñ a generic I/O panel
Ñ an NT7D47DA cable connected between the MVME712M card
and the Ethernet port of the generic I/O panel (refer to Table 93 for
the pinout of this cable)
Ñ an NT7D47EA drop cable connected between the Ethernet port of
the generic I/O panel and the Ethernet transceiver (refer to
Table 94 for the pinout of this cable)
For more information about the NT7D47DA and the NT7D47EA
cables, refer to Procedure 28: Installing the cables for Ethernet LAN
support (Application Module) in Chapter 17, ÒHardware upgrade.Ó