Setting Up Iscsi Software Initiator; Figure C-12: Iscsi Initiator Properties (General Tab) Screen - NEC Storage M100 Series User Manual

Disk array unit
Hide thumbs Also See for Storage M100 Series:
Table of Contents

Advertisement

User Guide
C.1.4 Setting up iSCSI Software Initiator
Settings for the Windows Server 2008 environment are described below.
1. Select the General tab in the iSCSI Initiator Properties screen to check the iqn (iSCSI Qualified
Name) shown as the Initiator name.
Click the Change button to change the iqn.
Click the Secret button when using the mutual CHAP authentication.
Click the Setup button when using the IPSec tunnel mode function. This is not supported.
Release 6.0

Figure C-12: iSCSI Initiator Properties (General Tab) Screen

The Secret setting for mutual CHAP authentication must also be set for
the disk array unit. The setting method is described in Section 15.3.21:
iSMcfg setldsetchap of NEC Storage Manager Command Reference.
Mutual CHAP authentication is also described in NEC Storage Manager
Command Reference as Bidirectional CHAP authentication.
CHAP authentication is also described in
Application Servers Registered with iSNS
Appendix C How to Set/Check Application Server (Windows) (iSCSI)
Appendix N: "Retrieve Initiator Information on
Server".