3.3 Connection

3.3.1 Overview

Check the following before connecting the disk array unit:
1. Connection cables
To connect the disk array unit and a disk enclosure, be sure to use the cables that come with the
disk enclosure or SAS cables specified by NEC.
(For FC) To connect a host bus adapter or FC switch on an application server to the disk array
unit, be sure to use an FC cable specified by NEC.
(For 1Gbps iSCSI) To connect an NIC or switch on an application server to the disk array unit, be
sure to use a LAN cable in the category 5e or over.
(For 10Gbps iSCSI) To connect an NIC or switch on an application server to the disk array unit,
be sure to use an optical Ethernet cable (conforming to 10GBASE-SR).
To connect the disk array to power supply, use the power supply cables that come with the disk
array unit.
2. Maximum cable length
a. FC cable
Host Interface
2 Gbps
4 Gbps
8 Gbps
b. iSCSI cable
Host Interface
1 Gbps
10 Gbps
Release 6.0
Max. Cable Length
300 m
150 m
50 m

Table 3-3: iSCSI Cable Length

Max. Cable Length
100 m
50 m (*1)
* 1. Connection of 50m or more is possible depending on the devices to be
connected. For more information, contact the technical division of NEC.

Table 3-2: FC Cable Length

Remarks
1000BASE-T
Optical cable
Connector: LC-LC
Core: 50 um
Type: MMF/OM2 cable
(All mode excitation bandwidth: 1500 MHz.km)