Checking Connection From Application Server; Check Connection Under A Windows Environment; Figure B-5: Computer Management - Device Manager - NEC Storage M100 Series User Manual

Disk array unit
Hide thumbs Also See for Storage M100 Series:
Table of Contents

Advertisement

User Guide
B.3 Checking Connection from Application Server
This section describes how to check connection under a Windows environment and check the
PathManager settings and status.
B.3.1 Check connection under a Windows environment
After confirming that the application server and disk array unit are connected through an FC cable,
restart the server and perform the following checks.
a. To start, select Administrative Tools > Computer Management > Device Manager.
b. Click Disk drives and check the number of logical disks.
Display example: When four logical disks are assigned to a server.
Release 6.0
Appendix B How to Set/Check Application Server (Windows) (FC/SAS)
If nothing is displayed, the OS was unable to recognize logical disks in the disk
array assigned to a server. Check the connection between the server and disk array
unit, the Access Control settings, host bus adapter driver settings, etc.

Figure B-5: Computer Management - Device Manager

Check the number of
Check the number of
NEC DISK ARRAY Multi-Path
NEC DISK ARRAY Multi-Path
Disk Device
Disk Device
316

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storage m300 series

Table of Contents