The following tables provide troubleshooting procedures. Confirm the error message indicated on the LCD, and verify it in the following list for the corresponding troubleshooting
remedy. If some parts need to be replaced or repaired, make sure to follow the procedure given in Chapter 4 "DISASSEMBLY/ASSEMBLY".
Occurrence
timing
Detailed phenomenon
CR position
• Power on
The Scanner Unit does not initialize when
the power is turned on.
• Anywhere
TROUBLESHOOTING
Table 3-4. Check point for Fatal error according to each phenomenon
Defective
unit/part name
1. Check if the Scanner Motor cable is connected to CN11
on the Main Board.
2. Check if the coil resistance of the Scanner Motor is about
38Ω*
Scanner Motor
Note *1: Manufactured by MITSUMI ELECTRIC CO. , LTD.
*2 : Manufactured by Oki Electric Industry Co., Ltd.
3. Check if the Scanner Motor Connector Cable is damaged. 3. Replace the Scanner Motor with a new one.