Tighten the screws in the order given in
Follow the steps below to install the Extension Spring 10.99 to
the Upper Paper Guide.
1.
Attach the one end of the Extension Spring 10.99 to the
hook of the Upper Paper Guide.
2.
Attach the other end of the Extension Spring 10.99 to the
hook of the Main Frame with longnose pliers.
Extension Spring 10.99
Hook
Figure 4-85. Installing the Extension Spring 10.99
DISASSEMBLY/ASSEMBLY

4.5.14 CR Unit

Figure.
4-83.
Hook
Disassembling the Printer Mechanism
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit/Left Frame/Front Frame/Right Frame/CR
Motor/CR Scale/Hopper/Main Frame Assy/Printhead
Removal procedure
1.
Remove the screw (x1) that secures the CR Scale Holder, and remove the CR
Scale Holder.
2.
Move the CR Unit in the direction of the arrow to remove the CR Unit.
CR Unit
Figure 4-86. Removing the CR Unit (1)
Revision A
CR Scale Holder
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)