Chapter 4 Disassembly/Assembly; Upper Scanner Housing - Epson WorkForce 600 Service Manual

Hide thumbs Also See for WorkForce 600:
Table of Contents

Advertisement

EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW
7.
Lift the rear side of the ADF Unit and release the hook (x1) of the ADF Cable
Cover from the hole of the Scanner Unit.
8.
Pull out the cables of the ADF Unit through the hole of the Scanner Unit, and
remove the ADF Unit.
Figure 4-117. Removing the ADF Unit (2)
Route the ADF Sensor cable and ADF Motor cable as shown in
the figure below before installing the Scanner Cable Cover.
Figure 4-118. Routing the ADF Cable
When installing the Scanner Cable Cover, first insert the rib
of the Scanner Cable Cover shown in
Lower Scanner Housing, then tighten the screw.
DISASSEMBLY/ASSEMBLY
ADF Cable Cover
Hook
Hole
ADF Unit
Route the ADF Sensor cable
over the ADF Motor cable
and hook it on the rib.
Fold the ADF
Sensor cable here.
Figure. 4-114
to the
Disassembling the Scanner Unit

4.6.2 Upper Scanner Housing

Parts/Components need to be removed in advance
Scanner Unit/ADF Unit
Removal procedure
Following work should be performed in a room where there is
C A U T I O N
a little dust. A clean room or a clean bench would be
preferable.
Do not scratch the Rod Lens Array when removing the CIS
Assy.
1.
Remove the screws (x7) securing the Upper Scanner Housing and remove the
Upper Scanner Housing.
Upper Scanner Housing
Top
Bottom
Figure 4-119. Removing the Upper Scanner Housing (1)
Revision A
C.B.P. 3x10, F/Zn-3C (5±1kgfcm)
136