Occurrence
timing
Detailed phenomenon
CR position
When turning on the power, the CR
Motor does not operate at all.
• Power on
• Anywhere
When turning on the power, the PF Motor
does not operate at all
TROUBLESHOOTING
Table 3-4. Check point for Fatal error according to each phenomenon
Defective
unit/part name
1. Check if the CR Motor Connector Cable is connected to
CN9 on the Main Board.
CR Motor
2. Check if the CR Motor Connector Cable is not damaged. 2. Replace the CR Motor with a new one.
3. Check if the CR Motor operates.
1. Check if the PF Motor Connector Cable is connected to
CN10 on the Main Board.
PF Motor
2. Check if the PF Motor Connector Cable is not damaged. 2. Replace the PF Motor with a new one.
3. Check if the PF Motor operates.
Error Indications and Fault Occurrence Causes
Check point
CR Motor
CN9
Connector Cable
PF Motor
Connector Cable
CN10
Revision A
Remedy
1. Connect the CR Motor Connector Cable to CN9
on the Main Board.
3. Replace the CR Motor with a new one.
1. Connect the PF Motor Connector Cable to
CN10 on the Main Board.
3. Replace the PF Motor with a new one.
Confidential