EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW
4.
Remove the screws (x5) that secure the Printer Mechanism, and remove the
Printer Mechanism by lifting it.
5
2
3
4
Figure 4-57. Removing the Printer Mechanism
DISASSEMBLY/ASSEMBLY
Printer Mechanism
1
C.B.P. 3x10, F/Zn-3C (6±1kgfcm)
Disassembling the Printer Mechanism
4.5.5 Left Frame
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit
Removal procedure
1.
Peel off the double sided tape that secures the PF Encoder FFC to the Left
Frame.
2.
Remove the screws (x2), and remove the grounding plate.
3.
Remove the screws (x3) that secure the Left Frame, and remove the Left
Frame.
Top
Left Frame
Grounding Plate
C.B.S. 3x6, F/Zn-3C (6±1kgfcm)
C.B.P. 3x10, F/Zn-3C (6±1kgfcm)
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
Positioning hole and dowel
Figure 4-58. Removing the Left Frame
Revision A
PF Encoder FFC
3
Double-sided
tape
1
2
115
Confidential