EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW
Occurrence
timing
Detailed phenomenon
CR position
• Power on
The Scanner Unit does not initialize when
the power is turned on.
• Anywhere
TROUBLESHOOTING
Table 3-4. Check point for Fatal error according to each phenomenon
Defective
unit/part name
1. Check if the Scanner Carriage FFC is connected to CN17
on the Main Board.
Scanner Carriage
FFC
2. Check if the Scanner Carriage FFC is damaged.
1. Check if the Scanner Carriage Unit is damaged.
Scanner Carriage
Unit
Error Indications and Fault Occurrence Causes
Check point
Scanner Carriage
FFC
CN17
Scanner Carriage Unit
Revision A
Remedy
1. Connect the Scanner Carriage FFC to CN17 on
the Main Board.
2. Replace the Scanner Carriage FFC with a new
one.
1. Replace the Scanner Carriage Unit with a new
one.
Confidential
51