V. EXPOSURE
A. Illuminating Assembly
1. Removing the Scanning Lamp
Caution:
1. Wait until the surface of the scanning
lamp has cooled before starting the work.
2. Do not leave fingerprints on the surface of
the scanning lamp (in particular, on the
transparent side).
3. If the surface of the scanning lamp is
soiled, dry wipe it.
1) Disconnect the power plug.
2) Remove the copyboard glass.
Figure 4-501
COPYRIGHT © 1996 CANON INC.
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. MECHANICAL SYSTEM
3) Remove the four screws, and remove the rear
cover.
4) Remove the feeder unit or the copyboard
cover; then, remove the two screws, and
remove the upper rear cover.
5) Disconnect the connector, and disengage the
hook assembly e; then, remove the scanner
cooling fan.
2
Figure 4-503
6) Move the No. 1 mirror mount so that it is as
shown when viewed from the rear.
7) Remove the screw, and remove the fluores-
cent lamp cover r; then, pull out the scan-
ning lamp.
4
Figure 4-504
3
4–27