5) Close the delivery assembly, and remove the
delivery assembly lower cover.
Caution:
The delivery assembly lower cover cannot
be removed unless the delivery assembly is
closed. Be sure to close the delivery assem-
bly after releasing the hook.
2. Removing the Delivery assembly
1) Disconnect the connector.
2) Open the delivery assembly, and remove the
screw w to remove the cable from the
machine (rear, front).
1
Figure 4-423
COPYRIGHT © 1996 CANON INC.
2
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. MECHANICAL SYSTEM
3) Pull out the spacer q from the right side of
the delivery assembly.
Figure 4-424
4) Release the bushing q by shifting it to the
left.
Figure 4-425
5) Move the delivery assembly to the right, and
disengage its left and then its right to remove.
1
1
4–25